Quantec Products

Anti-Bacterial Wipe Clean Pull Cord Accessory Pack

A simple and cost-effective means of updating existing ceiling pulls to comply with the stringent hygiene regulations of many health authorities and inspection bodies.

A BS8300 compliant anti-bacterial wipe-clean pull cord pack suitable for use with C-TEC's Quantec and 800 Series ceiling pull units.

Contains 3m of red vinyl encapsulated cord, two triangular bangles and a red fixing bullet.

Cord has integral properties that can help prevent the spread of infections such as MRSA, e. coli, c. diff, S Aureus, and the Norovirus.

Ideal for use in hospitals, nursing and care homes, doctors' surgeries, clinics, and any other area where infection control is imperative.

Easy to clean using a clean cloth and mild detergent.

Also compatible with many other manufacturers' ceiling pull units

Image
Image

C-TEC Ceiling Pull Cord Accessory Pack

Pull cord pack suitable for use with C-TEC's Quantec and 800 Series ceiling pull units. Also compatible with many other manufacturers' ceiling pull units.

Contains 3m of red nylon cord, two triangular bangles and a red fixing bullet.

C-TEC Quantec and 800 series Coiled Tail Call Lead

An extendable coiled tail call lead for use with C-TEC's Quantec and 800 Series Call Systems.

Allows users to remotely generate Standard calls from armchairs, beds, etc.

Comprises a pear-shaped call push, coiled 1.2 - 3.6m trailing lead and a 6.5mm remote jack plug.

Easily connects to the 6.35mm remote socket on compatible Quantec and 800 Series call points.

Activating the pear push or removing the tail call lead from a call point's remote socket will generate a Standard call.

Image
Image

Quantec Slave Ceiling Pull Unit

Can be used to generate a standard call on a Quantec Addressable Call System.

Typically wired as a slave to a Quantec Addressable Call Point or Quantec Accessible Toilet Reset Point.

Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles for ease of use by the infirm.

Red confidence LED and diffuser emits a bright red glow over a wide area to reassure the user that a call has been made.

Surface mountable.

Base fits 16mm conduit and BESA centres.

Also available as part of the Accessible Toilet Expansion Kit.

Infrared Patient Neck Pendant (Push for Call)

Allows patients in bedrooms and communal areas to remotely trigger standard calls via a Quantec infrared call point, ceiling receiver or radio receiver.

Alleviates the need for long, potentially hazardous tail call leads.

Supplied with an anti-ligature neck lanyard.

10m line-of-sight IR transmitting range.

Radio coverage dependent on the Quantec receiving device used.

Powered by a user-replaceable 12V alkaline battery.

Can be programmed with a unique User ID using a QT423 configurator, so staff can see who is calling.

Supplied with a sheet of coloured markable labels.

Image
Image

Infrared Patient Neck Pendant (Push for Attendance)

Allows nursing or security staff entering rooms during night shifts, etc., to log their attendance.

Upon activation, the infrared call point or ceiling receiver that picks up the Attendance call flashes to confirm the call has been registered.

All Attendance calls are logged together with the pendant's ID in Quantec's onboard datalogger or optional Surveyor Data Management Software.

10m line-of-sight IR transmitting range.

Powered by a user-replaceable 12V alkaline battery.

Allows managers to monitor which staff are performing their duties and to reassure users, relatives and regulatory authorities that patients and/or buildings are being checked periodically.

Must be used in conjunction with additional Quantec infrared devices.

Quantec Tail call lead 4.2 m (14ft)

A long 4.2m tail call lead for use with C-TEC's Quantec and 800 Series Call Systems.

Allows users to remotely generate Standard calls from armchairs, beds, etc.

Comprises a pear-shaped call push, 4.2m (14ft) trailing lead and a 6.35mm remote jack plug.

Easily connects to the 6.35mm remote socket on compatible Quantec and 800 Series call points.

Activating the pear push or removing the tail call lead from a call point's remote socket will generate a Standard call.

Image
Image

Quantec Tail Call Lead 1.8 m (6 FT)

A short 1.8mtail call lead for use with C-TEC's Quantec and 800 Series Call Systems.

Allows users to remotely generate Standard calls from armchairs, beds, etc.

Comprises a pear-shaped call push, 1.8m (6ft) trailing lead and a 6.35mm remote jack plug.

Easily connects to the 6.35mm remote socket on compatible Quantec and 800 Series call points.

Activating the pear push or removing the tail call lead from a call point's remote socket will generate a Standard call.

Hand or Foot pneumatic pad (for use in conjunction with air switch)

Ideal for people who find it difficult to press the buttons on standard tail call leads.

Must be used in conjunction with a separately available Air Switch.

Applying pressure to the pneumatic pad operates the highly sensitive air switch which in turn, when connected to a compatible call point’s remote socket via its 6.35mm remote jack, triggers a Standard call.

Image
Image

Air Switch for use with pneumatic pad

Designed for use with C-TEC's Pneumatic Pad.  Applying pressure to the pneumatic pad operates the air switch which in turn triggers a Standard call when the 6.35mm jack plug is connected to a compatible call point’s remote socket.

Operates at a minimum differential air pressure of 0.9 p.s.i. (pounds per square inch) or 6220 Pa (pascals) ± 10% at 16ºC.

Quantec Infrared Patient Wrist Pendant

Allows patients in bedrooms and communal areas to remotely trigger standard calls via a Quantec infrared call point, ceiling receiver or radio receiver.

Supplied on an adjustable wrist strap alleviating the need for long and potentially hazardous tail call leads.

10m line-of-sight IR transmitting range.

Radio coverage dependent on the Quantec receiving device used.

Powered by a user-replaceable 12V alkaline battery.

Can be programmed with a unique User ID so staff can see who is calling using a QT423 configurator.

Supplied with a sheet of coloured markable labels.

Image
Image

Quantec faceplate nut

Replacement hexagonal jack nut for use with Quantec call points.

Simply screw onto the jack socket to replace those lost or damaged.

Pack of 10

Quantec Addressable Call Point Button Reset c/w Remote Socket

A programmable addressable call point c/w remote jack socket for use with C-TEC's Quantec Addressable Call System.

Includes a Call button, Reset button and red/green confidence light.

Can make up to 5 levels of call - Standard, Ensuite, Help Required, Emergency, Presence & Attendance (dependent on configuration and ancillary devices used). Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.

Remote socket allows the connection of optional tail call leads, pressure mats, etc.

Can be programmed to operate in a multitude of ways using a QT423 configurator.

Connections provided for additional slave devices such as ceiling pulls, overdoor lights, slave infrared receivers and more.

QT602M magnetic reset version also available.

Image
Image

The C-TEC single magnetic reset key

Magnetic reset keys designed for use with the C-TEC Quantec and 800 Series call points, monitoring points and reset points with magnetic reset facility.  These keys allow the system to be reset by simply swiping the magnetic reset key past the reset call point, monitoring point, or reset point.

Quantec Addressable Call Point, Button Reset c/w Iconised Label & Remote Socket

A programmable addressable call point c/w iconised label and remote jack socket for use with C-TEC's Quantec Addressable Call System.

Includes a Call button, Reset button and red/green confidence light.

Can make up to 5 levels of call - Standard, Ensuite, Help Required, Emergency, Presence & Attendance (dependent on configuration and ancillary devices used). Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.

Remote socket allows the connection of optional tail call leads, pressure mats, etc.

Can be programmed to operate in a multitude of ways using a QT423 configurator.

Connections provided for additional slave devices such as ceiling pulls, overdoor lights, slave infrared receivers and more.

QT602EM magnetic reset version also available.

Image
Image

Quantec Addressable Call Point, Button Reset (No Remote)

A programmable Quantec addressable call point.

Includes a Call button, Reset button and red/green confidence light.

Can make up to 5 levels of call - Standard, Ensuite, Help Required, Emergency, Presence & Attendance (dependent on configuration and ancillary devices used). Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.

Can be programmed to operate in a multitude of ways using a QT423 configurator.

Connections provided for additional slave devices such as ceiling pulls, overdoor lights, slave infrared receivers and more.

QT609M magnetic reset version also available.

Quantec Products

Anti-Bacterial Wipe Clean Pull Cord Accessory Pack

A simple and cost-effective means of updating existing ceiling pulls to comply with the stringent hygiene regulations of many health authorities and inspection bodies.

A BS8300 compliant anti-bacterial wipe-clean pull cord pack suitable for use with C-TEC's Quantec and 800 Series ceiling pull units.

Contains 3m of red vinyl encapsulated cord, two triangular bangles and a red fixing bullet.

Cord has integral properties that can help prevent the spread of infections such as MRSA, e. coli, c. diff, S Aureus, and the Norovirus.

Ideal for use in hospitals, nursing and care homes, doctors' surgeries, clinics, and any other area where infection control is imperative.

Easy to clean using a clean cloth and mild detergent.

Also compatible with many other manufacturers' ceiling pull units

Image

C-TEC Ceiling Pull Cord Accessory Pack

Pull cord pack suitable for use with C-TEC's Quantec and 800 Series ceiling pull units. Also compatible with many other manufacturers' ceiling pull units.

Contains 3m of red nylon cord, two triangular bangles and a red fixing bullet.

Image

C-TEC Quantec and 800 series Coiled Tail Call Lead

An extendable coiled tail call lead for use with C-TEC's Quantec and 800 Series Call Systems.

Allows users to remotely generate Standard calls from armchairs, beds, etc.

Comprises a pear-shaped call push, coiled 1.2 - 3.6m trailing lead and a 6.5mm remote jack plug.

Easily connects to the 6.35mmremote socket on compatible Quantec and 800 Series call points.

Activating the pear push or removing the tail call lead from a call point's remote socket will generate a Standard call.

Image

Quantec Slave Ceiling Pull Unit

Can be used to generate a Standard or Ensuite call on a Quantec Addressable Call System.

Typically wired as a slave to a Quantec Addressable Call Point or Quantec Accessible Toilet Reset Point.

Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles for ease of use by the infirm.

Red confidence LED and diffuser emits a bright red glow over a wide area to reassure the user that a call has been made.

Surface mountable.

Base fits 16mm conduit and BESA centres.

Also available as part of the Accessible Toilet Expansion Kit.

Image

Infrared Patient Neck Pendant (Push for Call)

Allows patients in bedrooms and communal areas to remotely trigger standard calls via a Quantec infrared call point, ceiling receiver or radio receiver.

Alleviates the need for long, potentially hazardous tail call leads.

Supplied with an anti-ligature neck lanyard.

10m line-of-sight IR transmitting range.

Radio coverage dependent on the Quantec receiving device used.

Powered by a user-replaceable 12V alkaline battery.

Can be programmed with a unique User ID using a QT423 configurator, so staff can see who is calling.

Supplied with a sheet of coloured markable labels.

Image

Infrared Patient Neck Pendant (Push for Attendance)

Allows nursing or security staff entering rooms during night shifts, etc., to log their attendance.

Upon activation, the infrared call point or ceiling receiver that picks up the Attendance call flashes to confirm the call has been registered.

All Attendance calls are logged together with the pendant's ID in Quantec's onboard datalogger or optional Surveyor Data Management Software.

10m line-of-sight IR transmitting range.

Powered by a user-replaceable 12V alkaline battery.

Allows managers to monitor which staff are performing their duties and to reassure users, relatives and regulatory authorities that patients and/or buildings are being checked periodically.

Must be used in conjunction with additional Quantec infrared devices.

Image

Quantec Tail call lead 4.2 m (14ft)

A long 4.2m tail call lead for use with C-TEC's Quantec and 800 Series Call Systems.

Allows users to remotely generate Standard calls from armchairs, beds, etc.

Comprises a pear-shaped call push, 4.2m (14ft) trailing lead and a 6.35mm remote jack plug.

Easily connects to the 6.35mm remote socket on compatible Quantec and 800 Series call points.

Activating the pear push or removing the tail call lead from a call point's remote socket will generate a Standard call.

Image

Quantec Tail Call Lead 1.8 m (6 FT)

A short 1.8mtail call lead for use with C-TEC's Quantec and 800 Series Call Systems.

Allows users to remotely generate Standard calls from armchairs, beds, etc.

Comprises a pear-shaped call push, 1.8m (6ft) trailing lead and a 6.35mm remote jack plug.

Easily connects to the 6.35mmremote socket on compatible Quantec and 800 Series call points.

Activating the pear push or removing the tail call lead from a call point's remote socket will generate a Standard call.

Image

Hand or Foot pneumatic pad (for use in conjunction with air switch)

Ideal for people who find it difficult to press the buttons on standard tail call leads.

Must be used in conjunction with a separately available Air Switch.

Applying pressure to the pneumatic pad operates the highly sensitive air switch which in turn, when connected to a compatible call point’s remote socket via its 6.35mm remote jack, triggers a Standard call.

Image

Air Switch for use with pneumatic pad

Designed for use with C-TEC's Pneumatic Pad.  Applying pressure to the pneumatic pad operates the air switch which in turn triggers a Standard call when the 6.35mm jack plug is connected to a compatible call point’s remote socket.

Operates at a minimum differential air pressure of 0.9 p.s.i. (pounds per square inch) or 6220 Pa (pascals) ± 10% at 16ºC.

Image

Quantec Infrared Patient Wrist Pendant

Allows patients in bedrooms and communal areas to remotely trigger standard calls via a Quantec infrared call point, ceiling receiver or radio receiver.

Supplied on an adjustable wrist strap alleviating the need for long and potentially hazardous tail call leads.

10m line-of-sight IR transmitting range.

Radio coverage dependent on the Quantec receiving device used.

Powered by a user-replaceable 12V alkaline battery.

Can be programmed with a unique User ID so staff can see who is calling using a QT423 configurator.

Supplied with a sheet of coloured markable labels.

Image

Quantec faceplate nut

Replacement hexagonal jack nut for use with Quantec call points.

Simply screw onto the jack socket to replace those lost or damaged.

Pack of 10

Image

Quantec Addressable Call Point Button Reset c/w Remote Socket

A programmable addressable call point c/w remote jack socket for use with C-TEC's Quantec Addressable Call System.

Includes a Call button, Reset button and red/green confidence light.

Can make up to 5 levels of call - Standard, Ensuite, Help Required, Emergency, Presence & Attendance (dependent on configuration and ancillary devices used). Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.

Remote socket allows the connection of optional tail call leads, pressure mats, etc.

Can be programmed to operate in a multitude of ways using a QT423 configurator.

Connections provided for additional slave devices such as ceiling pulls, overdoor lights, slave infrared receivers and more.

QT602M magnetic reset version also available.

Image

The C-TEC single magnetic reset key

Magnetic reset keys designed for use with the C-TEC Quantec and 800 Series call points, monitoring points and reset points with magnetic reset facility.  These keys allow the system to be reset by simply swiping the magnetic reset key past the reset call point, monitoring point, or reset point.

Image

Quantec Addressable Call Point, Button Reset c/w Iconised Label & Remote Socket

A programmable addressable call point c/w iconised label and remote jack socket for use with C-TEC's Quantec Addressable Call System.

Includes a Call button, Reset button and red/green confidence light.

Can make up to 5 levels of call - Standard, Ensuite, Help Required, Emergency, Presence & Attendance (dependent on configuration and ancillary devices used). Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.

Remote socket allows the connection of optional tail call leads, pressure mats, etc.

Can be programmed to operate in a multitude of ways using a QT423 configurator.

Connections provided for additional slave devices such as ceiling pulls, overdoor lights, slave infrared receivers and more.

QT602EM magnetic reset version also available.

Image

Quantec Addressable Call Point, Button Reset (No Remote)

A programmable Quantec addressable call point.

Includes a Call button, Reset button and red/green confidence light.

Can make up to 5 levels of call - Standard, Ensuite, Help Required, Emergency, Presence & Attendance (dependent on configuration and ancillary devices used). Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.

Can be programmed to operate in a multitude of ways using a QT423 configurator.

Connections provided for additional slave devices such as ceiling pulls, overdoor lights, slave infrared receivers and more.

QT609M magnetic reset version also available.

Image